<Error>
<ErrorNumber>15076</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: trailing edge clamps not on actuator
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
If all the clamps are in place, check for faulty magnet sensor by using "tec" command. If it is
faulty, use "set al ms 0" to bypass the sensor and get the customer going. Arrange for field service.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check if all the clamps are on the actuator. Place any missing clamp onto the actuator and select
resume.
</text></DescriptionText>
</OperatorAction>
<Cause>
Missing clamp on the TEC actuator
</Cause>
<Cause>
Faulty TEC magnet sensor
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_ms.xml</LinkAddress><LinkTitle>NVS: al ms</LinkTitle></Link>
<Link><LinkAddress>../commands/tec.xml</LinkAddress><LinkTitle>Command: tec</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:51 2008 PST
</Updated>
<Links>
</Links>